Background

A Heartbeat signal is required from your application to our monitoring system. This is intended to provide a basic monitoring facility to our operational staff to detect outages before they are reported. 

...

  • An HTTP POST request to a monitoring server within the local network
  • The application should have a configurable monitoring server IP address and port.
  • Example of payload / body: “{ arg: { version: "1.0.1", localtime: “2018-11-16T12:34:23.234Z” } }”
  • Configurable heartbeat interval with a default of 120 seconds
  • Configurable on/off state to enable or disable the heartbeat
  • The overall experience is not impacted by a slow response from the monitoring service.

...

  • arg: object  containing:
    • version: string – release number (following semantic versioning)
    • localtime: string – local time of the device (ISO8601) YYYY-MM-DDTHH:mm:ss.sssZ

Testing

You can test your heartbeat by posting to port 443 on httpson https://heartbeatdev.exhibition.tepapa.govt.nz/heartbeat/<product-name>

Please note this is an interim testing endpoint using SSL - you do not need to support SSL in your interactive, an HTTP endpoint will be available soon.

...